Junior Engineer (Electrical/Electronics) MCQs – Series 5 (Q61-70)

Q61. The main purpose of a surge arrester in a power system is to:

  • A) Reduce transmission line losses
  • B) Improve system power factor
  • C) Protect equipment from lightning and switching surges
  • D) Regulate steady-state voltage

Q62. Corona loss in overhead transmission lines increases with:

  • A) Larger conductor spacing only
  • B) Lower line voltage
  • C) Smaller conductor diameter and higher line voltage
  • D) Larger conductor diameter

Q63. The main reason electrical power is transmitted at high voltage is to:

  • A) Reduce current and thus reduce I²R losses
  • B) Increase conductor cross-section
  • C) Increase current and reduce voltage drop
  • D) Reduce insulation requirements

Q64. Which type of insulator is typically used at the dead ends and sharp turns of transmission lines?

  • A) Suspension insulator
  • B) Pin insulator
  • C) Strain insulator
  • D) Shackle insulator

Q65. The Ferranti effect on transmission lines refers to the condition where:

  • A) Receiving-end voltage exceeds sending-end voltage on a lightly loaded long line
  • B) The line is heavily loaded and voltage drops sharply
  • C) Sending-end voltage always exceeds receiving-end voltage
  • D) Voltage remains constant regardless of loading

Q66. The purpose of bus-bar protection in a substation is to:

  • A) Reduce transmission losses
  • B) Improve the system’s power factor
  • C) Regulate the substation voltage
  • D) Quickly isolate a faulty section of the bus to protect connected equipment

Q67. Economic load dispatch in power system operation aims to:

  • A) Equalize the loading on all generating units
  • B) Maximize transmission losses across the network
  • C) Minimize only the system voltage
  • D) Minimize total generation cost while meeting system demand

Q68. The most common method for grounding the neutral point of distribution transformers is:

  • A) Leaving the neutral completely floating
  • B) Solid or resistance grounding
  • C) Capacitive grounding only
  • D) Grounding through an air gap only

Q69. Which protective relay operates by comparing the current entering and leaving a protected zone?

  • A) Overcurrent relay
  • B) Distance relay
  • C) Buchholz relay
  • D) Differential relay

Q70. The main function of a Buchholz relay is to:

  • A) Measure the load current of the transformer
  • B) Improve the power factor of the transformer
  • C) Regulate transformer output voltage
  • D) Protect oil-filled transformers from internal faults by detecting gas accumulation